Improved Accuracy Metallic Resonator CVG
Improved Accuracy Metallic Resonator CVG
复制标题
DOI:
10.1109/maes.2009.5109952
复制
发表时间:
2009-05-01
影响因子:
3.6
通讯作者:
Taturin, V. N.
中科院分区:
文献类型:
--
作者:
Chikovani, V. V.;Yatsenko, Yu. A.;Taturin, V. N.
Metallic resonator Q-factor is very sensitive to the resonator's material, its thermal and chemical treatment, design, and environment; i.e., pressure and temperature. In order to obtain higher accuracy for CVG it is necessary to use resonator evacuation.Resonator mass plays a very important role in sensitivity to angle rate, in stability of vibration, in response to environmental condition changes, and also to external vibration and shock resistance. Innalabs Holding Inc. uses a cylindrical resonator with increased rim thickness of up to 2 mm and more.This concerns resonator material and design parameters selection, material thermal treatment to increase resonator Q-factor, and improved control algorithms in order to increase metallic CVG accuracy. As a result, CVG bias instability of 0.025 deg/h and random walk of 0.008 degvh for the resonator diameter 43 mm, and 0.2 deg/h for the resonator diameter 25 mm were obtained. Future opportunities for Innalabs CVG is also discussed herein.Test results are presented for CVG43 and CVG25. Three-axis CVG unit under control of one DSP "Sharc" and IMU parameters are forecasted.