Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
复制标题
DOI:
10.1038/nphoton.2016.41
复制
发表时间:
2016-05-01
期刊:
影响因子:
35
通讯作者:
Huang, Jinsong
中科院分区:
文献类型:
--
作者:
Wei, Haotong;Fang, Yanjun;Huang, Jinsong
The large mobilities and carrier lifetimes of hybrid perovskite single crystals and the high atomic numbers of Pb, I and Br make them ideal for X-ray and gamma-ray detection. Here, we report a sensitive X-ray detector made of methylammonium lead bromide perovskite single crystals. A record-high mobility-lifetime product of 1.2 x 10(-2) cm(2) V-1 and an extremely small surface charge recombination velocity of 64 cm s(-1) are realized by reducing the bulk defects and passivating surface traps. Single-crystal devices with a thickness of 2-3 mm show 16.4% detection efficiency at near zero bias under irradiation with continuum X-ray energy up to 50 keV. The lowest detectable X-ray dose rate is 0.5 mu Gy(air) s(-1) with a sensitivity of 80 mu C Gy(air)(-1) cm(-2), which is four times higher than the sensitivity achieved with alpha-Se X-ray detectors. This allows the radiation dose applied to a human body to be reduced for many medical and security check applications.