Nanometer focusing of hard x rays by phase zone plates
Nanometer focusing of hard x rays by phase zone plates
复制标题
DOI:
10.1063/1.1149744
复制
发表时间:
1999-05
影响因子:
1.6
通讯作者:
W. Yun;B. Lai;Z. Cai;J. Maser;D. Legnini;E. Gluskin;Zheng Chen;A. Krasnoperova;Y. Vladimirsky;F. Cerrina;E. Fabrizio;M. Gentili
中科院分区:
文献类型:
--
作者:
W. Yun;B. Lai;Z. Cai;J. Maser;D. Legnini;E. Gluskin;Zheng Chen;A. Krasnoperova;Y. Vladimirsky;F. Cerrina;E. Fabrizio;M. Gentili
Focusing of 8 keV x rays to a spot size of 150 and 90 nm full width at half maximum have been demonstrated at the first- and third-order foci, respectively, of a phase zone plate (PZP). The PZP has a numerical aperture of 1.5 mrad and focusing efficiency of 13% for 8 keV x rays. A flux density gain of 121 000 was obtained at the first-order focus. In this article, the fabrication of the PZP and its experimental characterization are presented and some special applications are discussed.