Timing detectors with SiPM read-out for the MUSE experiment at PSI
Timing detectors with SiPM read-out for the MUSE experiment at PSI
复制标题
用于 PSI 的 MUSE 实验的具有 SiPM 读出功能的定时探测器
DOI:
10.1016/j.nima.2020.164801
复制
发表时间:
2021
期刊:
影响因子:
--
通讯作者:
Collicott, C.
中科院分区:
文献类型:
--
作者:
Rostomyan, T.;Cline, E.;Lavrukhin, I.;Atac, H.;Atencio, A.;Bernauer, J.C.;Briscoe, W.J.;Cohen, D.;Cohen, E.O.;Collicott, C.
The Muon Scattering Experiment at the Paul Scherrer Institute uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
登录
查看更多内容
DOI:
--
发表时间:
2013
期刊:
影响因子:
--
作者:
S. Brunner;L. Gruber;J. Marton;H. Orth;K. Suzuki
通讯作者:
K. Suzuki
DOI:
10.1016/j.nima.2016.01.044
发表时间:
2016
影响因子:
1.4
作者:
E. Cohen;E. Piasetzky;Y. Shamai;N. Pilip
通讯作者:
N. Pilip
DOI:
--
发表时间:
2017
期刊:
影响因子:
--
作者:
R. Gilman;E. Downie;G. Ron;S. Strauch;A. Afanasev;A. Akmal;J. Arrington;H. Atac;C. Ayerbe;F. Benmokhtar;N. Benmouna;J. Bernauer;A. Blomberg;W. Briscoe;D. Cioffi;E. Cline;D. Cohen;E. Cohen;C. Collicott;K. Deiters;J. Diefenbach;B. Dongwi;D. Ghosal;A. Golossanov;R. Gothe;D. Higinbotham;D. Hornidge;Y. Ilieva;N. Kalantarians;M. Kohl;B. Krusche;G. Kumbartzki;I. Lavrukhin;L. Li;J. Lichtenstadt;W. Lin;A. Liyanage;W. Lorenzon;K. Mesick;Z. Meziani;P. Mohanmurthy;P. Moran;J. Nazeer;E. Piasetzsky;R. Ransome;R. Raymond;D. Reggiani;P. Reimer;A. Richter;T. Rostomyan;P. Roy;A. Sarty;Y. Shamai;N. Sparveris;N. Steinberg;I. Strakovsky;V. Sulkosky;A. Tadepalli;M. Taragin
通讯作者:
M. Taragin
DOI:
10.1016/0029-554x(78)90298-7
发表时间:
1978
期刊:
Nuclear Instruments and Methods
影响因子:
--
作者:
R. Balsiger;B. Berkes;D. Brombach;D. George;M. Ianovici;E. Pedroni;O. Szavits;M. Werner;J. Zichy;E. Boschitz;J. Egger;C. Wiedner
通讯作者:
C. Wiedner
DOI:
10.22323/1.322.0026
发表时间:
2019
期刊:
5th International Conference on Micro-Pattern Gas Detectors (MPGD2017
影响因子:
--
作者:
Liyanage, Anusha;Kohl, Michael;Nazeer, Jesmin;Patel, Tanvi
通讯作者:
Patel, Tanvi