Rare double orifice mitral valve malformation associated with bicuspid aortic valve in Turner syndrome: diagnosed by a series of novel three-dimensional echocardiography and literature review.
Rare double orifice mitral valve malformation associated with bicuspid aortic valve in Turner syndrome: diagnosed by a series of novel three-dimensional echocardiography and literature review.
复制标题
特纳综合征罕见双口二尖瓣畸形合并二尖瓣主动脉瓣:一系列新型三维超声心动图诊断及文献综述
DOI:
10.1186/s12872-021-02184-2
复制
发表时间:
2021-08-04
影响因子:
2.1
通讯作者:
Ren W
中科院分区:
文献类型:
--
作者:
Sun F;Tan X;Sun A;Zhang X;Liang Y;Ren W
Patients with both double orifice mitral valve (DOMV) and bicuspid aortic valve (BAV) malformation are rare. Although DOMV or BAV can be detected in some genetic syndromes, it has not been reported to simultaneously appear in Turner syndrome (TS). TrueVue, TouchVue, and TrueVue Glass are the latest technologies in advanced three-dimensional echocardiography (3DE), which is an important information supplement to two-dimensional echocardiography (2DE) for the diagnosis of congenital cardiac malformations. Herein we report the novel use of the above-mentioned technologies in the diagnosis and evaluation of a rare, combined valve malformation. Meanwhile, we also reviewed the literature for cases involving both DOMV and BAV and their association with various genetic syndromes. We present the case of a 5-year-old girl diagnosed with TS because of a developmental delay. DOMV and BAV were found through echocardiographic examination. Three-dimensional transthoracic echocardiography as well as a series of novel advanced techniques were applied to clearly display the spatial structure of all tiers of the mitral valve apparatus, aortic valve, and arch to facilitate an accurate diagnosis. This is the first case in which both DOMV and BAV were associated with TS. Innovative TrueVue and TrueVue Glass offer unprecedented photographic stereoscopic images, while TouchVue technology greatly improved the ultrasonic diagnostic workflow and the diagnostic performance of rare valve malformations by adding virtual light sources to display realistic light-shadow effects. The online version contains supplementary material available at 10.1186/s12872-021-02184-2.
登录
查看更多内容
影响因子:
0.7
作者:
Khani, Mohammad;Rohani, Atoosheh
通讯作者:
Rohani, Atoosheh
DOI:
10.1111/echo.12382
发表时间:
2014-01-01
影响因子:
1.5
作者:
Kocabas, Abdullah;Ekici, Filiz;Aktas, Dogukan
通讯作者:
Aktas, Dogukan
影响因子:
3.5
作者:
Sun, Feifei;Chen, Yixin;Li, Dongyu
通讯作者:
Li, Dongyu
影响因子:
2.8
作者:
BANORODRIGO, A;VANPRAAGH, S;VANPRAAGH, R
通讯作者:
VANPRAAGH, R
影响因子:
0.9
作者:
Karas, S;Barbetseas, J;Toutouzas, P
通讯作者:
Toutouzas, P