Evaluation of the cumulative Cherenkov converted dose on TSET patients with multiple Cherenkov cameras.
Evaluation of the cumulative Cherenkov converted dose on TSET patients with multiple Cherenkov cameras.
复制标题
使用多个切伦科夫相机评估 TSET 患者的累积切伦科夫转换剂量。
DOI:
10.1117/12.2651177
复制
发表时间:
2023
期刊:
影响因子:
--
通讯作者:
Zhu,TimothyC
中科院分区:
文献类型:
--
作者:
Zhu,Yifeng;Alexander,DanielA;Miao,Tianshun;Maity,Amit;Plastaras,JohnP;Paydar,Ima;LaRiviere,Michael;Pogue,BrianW;Zhu,TimothyC
Cherenkov images can be used for the quality assurance of dose homogeneity in total skin electron therapy (TSET). For the dose mapping purpose, this study reconstructed the patient model from 3D scans using registration algorithms and computer animation techniques. The Cherenkov light emission of the patient’s surface was extracted from multi-view Cherenkov images, converted into dose distribution, and projected onto the patient’s 3D model, allowing for dose cumulation and evaluation. The projected result from multiple Cherenkov cameras provides additional information about Cherenkov emission on the sides of the patients, which improves the agreement between the Cherenkov converted dose and the OSLD measurements.