Revised viscosities of saturated liquid halocarbon refrigerants from 273 to 353 K

Revised viscosities of saturated liquid halocarbon refrigerants from 273 to 353 K
复制标题

DOI:
10.1023/a:1006666308831
复制
发表时间:
2000-07-01
影响因子:
2.2
通讯作者:
Yokoyama, C
Yokoyama, C
中科院分区:
工程技术4区
文献类型:
--
作者:
Kumagai, A;Yokoyama, C

文献摘要

被引文献

相似文献

本文对文献[1,2]中报道的R11,R1, 2,R22,R13 B1,R152 a,R113,R123,R123 a,R143 a,R114,R134 a,R141 b,R142 b,R225 ca,R225 cb等15种卤代烃制冷剂的饱和液体粘度进行了修正,并对修正后的饱和液体粘度进行了计算。其中未对密封毛细管粘度计进行蒸汽浮力校正。最大校正量从R225 cb的1.2%到R143 a的17.4%。除了低蒸汽密度制冷剂R11、R123、R123 a、R113、R141 b、R225 ca和R125 cb的最大修正值为2.4%外,我们以前论文中的错误数据应被视为过时。
This paper presents revised saturated liquid viscosities for 15 halocarbon refrigerants, that is, R11, R12, R22, R13B1, R152a, R113, R123, R123a, R143a, R114, R134a, R141b, R142b, R225ca, and R225cb, reported in our previous papers [1,2], in which the vapor buoyancy correction for the sealed capillary viscometer was not applied. The maximum corrections amount to from 1.2% for R225cb to 17.4% for R143a. The erroneous data in our previous papers should be considered obsolete except for the low-vapor density refrigerants R11, R123, R123a, R113, R141b, R225ca, and R125cb, for which the maximum correction is 2.4%.