"Multi-Loop Feedback System for Dynamitron Voltage Regulation"

"Multi-Loop Feedback System for Dynamitron Voltage Regulation"
复制标题

“用于发电机电压调节的多环反馈系统”

DOI:
10.1109/tns.1967.4324546
复制
发表时间:
1967
影响因子:
1.8
通讯作者:
C. C. Thompson
C. C. Thompson
中科院分区:
工程技术3区
文献类型:
--
作者:
C. C. Thompson

文献摘要

被引文献

相似文献

Dynamitron高压发生器的稳定性受以下几个因素影响:1)射束负载变化,2)电源变化,3)振荡管直流阳极电源中的频率分量,以及4)由于交流引起的调制。加热灯丝。根据实验获得的数据和稳定的原因,通过一个多回路反馈系统产生的电压的简要分析。在3.0MeV加速器上进行的测量表明,终端涟漪为1500伏峰-峰,束流从0到6毫安的调节小于±1500伏。发电机和调节电子设计的未来改进应能将涟漪降至600 V峰峰值,并将调节降至±600 V。
The stability of the Dynamitron high voltage generator is influenced by several factors: 1) beam load changes, 2) changes in the power mains, 3) frequency components in d.c. anode power to the oscillator tubes, and 4) modulation due to a.c. heated filaments. A brief analysis based on experimentally obtained data and the reasons for stabilizing the generated voltage by means of a multi-loop feedback system are presented. Measurements made on a 3.0MeV accelerator show that terminal ripple is 1500 volts peak-to-peak and that the regulation from zero to six milliamperes of beam is less than ±1500 volts. Future improvements in the generator and regulating electronics design should result in reducing the ripple to 600 volts peak-to-peak and the regulation to ±600 volts.