Trace elemental analysis of drugs of abuse using synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF).
Trace elemental analysis of drugs of abuse using synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF).
复制标题
使用同步辐射全反射 X 射线荧光分析 (SR-TXRF) 对滥用药物进行微量元素分析。
DOI:
10.1520/jfs15500j
复制
发表时间:
2002
影响因子:
1.6
通讯作者:
J. Matsui
中科院分区:
文献类型:
--
作者:
Seiji Muratsu;T. Ninomiya;Y. Kagoshima;J. Matsui
Synchrotron radiation total reflection X-ray fluorescence spectroscopy (SR-TXRF) was utilized to analyze various trace elements in small amounts of drugs of abuse. Sample amounts of 1 microL solutions containing 10 microg of drugs (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, and heroin) were spotted on silicon wafers for direct analysis. In addition, a leaflet of marijuana was set directly on a silicon wafer, and opium in the form of a soft lump was smeared on another silicon wafer for analysis. In these experiments, about 10 pg of contaminant elements could be detected. For example, in a seized methamphetamine sample, iodine was found, which could be indicative of synthetic route. In seized 3,4-methylenedioxymethamphetamine samples, variable amounts of phosphorus, calcium, sulfur, and potassium were found, which could not be detected in a control 3,4-methylenedioxymethamphetamine sample. For marijuana and opium, two spectral patterns were obtained that were far different from each other and could be easily discriminated. Using SR-TXRF, pg amounts of each trace element in 10 microg of various drugs can be easily detected, which is not the case either for a standard TXRF experimental system or for other elemental analysis techniques.