Registration of Multiview Echocardiography Sequences Using a Subspace Error Metric

Registration of Multiview Echocardiography Sequences Using a Subspace Error Metric
复制标题

使用子空间误差度量注册多视图超声心动图序列

DOI:
10.1109/tbme.2016.2550487
复制
发表时间:
2017
影响因子:
4.6
通讯作者:
Peressutti D
Peressutti D
中科院分区:
工程技术2区
文献类型:
--
作者:
Peressutti D

文献摘要

参考文献

被引文献

相似文献

Objective3-Dechocardiography (3DtE) is widely employed for the assessment of left ventricular anatomy and function. However, the information derived from 3DtE images can be affected by the poor image quality and the limited field of view. Registration of multiview 3DtE sequences has been proposed to compound images from different acoustic windows, therefore improving both image quality and coverage. We propose a novel subspace error metric for an automatic and robust registration of multiview intrasubject 3DtE sequences.MethodsThe proposed metric employs linear dimensionality reduction to exploit the similarity in the temporal variation of multiview 3DtE sequences. The use of a low-dimensional subspace for the computation of the error metric reduces the influence of image artefacts and noise on the registration optimization, resulting in fast and robust registrations that do not require a starting estimate.ResultsThe accuracy, robustness, and execution time of the proposed registration were thoroughly validated. Results on 48 pairwise multiview 3DtE registrations show the proposed error metric to outperform a state-of-the-art phase-based error metric, with improvements in median/75th percentile of the target registration error of 21%/31% and an improvement in mean execution time of 45%.ConclusionThe proposed subspace error metric outperforms sum-of-squared differences and phase-based error metrics for the registration of multiview 3DtE sequences in terms of accuracy, robustness, and execution time.SignificanceThe use of the proposed subspace error metric has the potential to replace standard image error metrics for a robust and automatic registration of multiview 3DtE sequences.
多视图微分同像配准:在 3D 超声心动图运动和应变估计中的应用
DOI: 10.1016/j.media.2013.01.002
发表时间: 2013
影响因子: 10.9
作者:
G. Piella;M. D. Craene;C. Butakoff;V. Grau;Cheng Yao;S. Nedjati;G. Penney;Alejandro F Frangi
通讯作者: Alejandro F Frangi
使用基于强度的图像配准进行超声校准:适用于心导管插入术程序
DOI: 10.1117/12.770174
发表时间: 2008
影响因子: 3.5
作者:
Y. Ma;K. Rhode;G. Gao;A. King;Phani Chinchapatnam;T. Schaeffter;D. Hawkes;R. Razavi;G. Penney
通讯作者: G. Penney
DOI: --
发表时间: --
期刊: --
影响因子: --
作者:
C. Wachinger;W. Wein;Nassir Navab
通讯作者: Nassir Navab
DOI: 10.1016/j.jcmg.2010.03.010
发表时间: 2010-07-01
影响因子: 14
作者:
Szmigielski, Cezary;Rajpoot, Kashif;Becher, Harald
通讯作者: Becher, Harald
一种基于内部相似性的多模态基于强度的相似性度量的新框架
DOI: 10.1117/12.769402
发表时间: 2008
期刊: --
影响因子: --
作者:
G. Penney;Lewis D. Griffin;A. King;D. Hawkes
通讯作者: D. Hawkes