Facility Hemodialysis Vascular Access Use and Mortality in Countries Participating in DOPPS: An Instrumental Variable Analysis
Facility Hemodialysis Vascular Access Use and Mortality in Countries Participating in DOPPS: An Instrumental Variable Analysis
复制标题
DOI:
10.1053/j.ajkd.2008.10.043
复制
发表时间:
2009-03-01
影响因子:
13.2
通讯作者:
Port, Friedrich K.
中科院分区:
文献类型:
--
作者:
Pisoni, Ronald L.;Arrington, Charlotte J.;Port, Friedrich K.
Background: Previously, the Dialysis Outcomes and Practice Patterns Study (DOPPS) has shown large international variations in vascular access practice. Greater mortality risks have been seen for hemodialysis (HD) patients dialyzing with a catheter or graft versus a native arteriovenous fistula (AVF). To further understand the relationship between vascular access practice and outcomes, we have applied practice-based analyses (using an instrumental variable approach) to decrease the treatment-by-indication bias of prior patient-level analyses.Study Design: A prospective observational study of HD practices.Setting & Participants: Data collected from 1996 to 2004 from 28,196 HD patients from more than 300 dialysis units participating in the DOPPS in 12 countries.Predictor or Factor: Patient-level or case-mix-adjusted facility-level vascular access use.Outcomes/Measurements: Mortality and hospitalization risks.Results: After adjusting for demographics, comorbid conditions, and laboratory values, greater mortality risk was seen for patients using a catheter (relative risk, 1.32; 95% confidence interval, 1.22 to 1.42; P < 0.001) or graft (relative risk, 1.15; 95% confidence interval, 1.06 to 1.25; P < 0.001) versus an AVF. Every 20% greater case-mix-adjusted catheter use within a facility was associated with 20% greater mortality risk (versus facility AVF use, P < 0.001); and every 20% greater facility graft use was associated with 9% greater mortality risk (P < 0.001). Greater facility catheter and graft use were both associated with greater all-cause and infection-related hospitalization. Catheter and graft use were greater in the United States than in Japan and many European countries. More than half the 36% to 43% greater case-mix-adjusted mortality risk for HD patients in the United States versus the 5 European countries from the DOPPS I and II was attributable to differences in vascular access practice, even after adjusting for other HD practices. Vascular access practice differences accounted for nearly 30% of the greater US mortality compared with Japan.Limitations: Possible existence of unmeasured facility- and patient-level confounders that could impact the relationship of vascular access use with outcomes.Conclusions: Facility-based analyses diminish treatment-by-indication bias and suggest that less catheter and graft use improves patient survival.