Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study

Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study
复制标题

DOI:
10.1007/s00261-016-0702-2
复制
发表时间:
2016-08-01
影响因子:
2.4
通讯作者:
Yeh, Benjamin M.
Yeh, Benjamin M.
中科院分区:
医学3区
文献类型:
--
作者:
Winklhofer, Sebastian;Lambert, Jack W.;Yeh, Benjamin M.

文献摘要

被引文献

相似文献

目的:本研究的目的是评估快速千伏开关(RS)双能量计算机断层扫描(DECT),以减少乳腺癌相关的条纹artifaction.Methods:100例连续患者(48名男性,52名女性,平均年龄57岁)的rsDECT图像的能力进行了回顾性评价,在这个机构审查委员会批准的研究。图像重建包括虚拟单色70和120 keV图像,以及碘(-水)和水(-碘)材料分解图像。我们定性(4分制)和定量(碘/水浓度、Hounsfield单位、灰度值(戈伊))记录伪影的存在和严重程度,并与相应的未受影响的参考组织进行比较。类似的措施,在DECT图像的乳房假体。Wilcoxon符号秩和配对t检验被用来比较不同的图像reconstruction.Results:蠕动相关的条纹伪影被发现在49(49%)的DECT检查之间的结果。70、120和水(-碘)图像中的伪影比碘(-水)图像中的伪影严重得多(定性读数P < 0.001)。在70、120 keV和水(-碘)图像中,伪影和参考组织之间的定量测量值存在显著差异(每次图像重建的HU和戈伊均为P < 0.001),但在碘(-水)图像中无显著差异(碘浓度P = 0.088和戈伊P = 0.111)。类似的结果被认为是在pathesis DECT幻影study.Conclusions:蠕动相关的条纹伪影看到70,120 keV,和水(碘)图像大幅减少碘(水)图像在rsDECT。
Objective: The purpose of the study was to assess the ability of rapid-kV switching (rs) dual-energy computed tomography (DECT) to reduce peristalsis-related streak artifact.Methods: rsDECT images of 100 consecutive patients (48 male, 52 female, mean age 57 years) were retrospectively evaluated in this institutional review board-approved study. Image reconstructions included virtual monochromatic 70 and 120 keV images, as well as iodine(-water) and water(-iodine) material decomposition images. We recorded the presence and severity of artifacts qualitatively (4-point scale) and quantitatively [iodine/water concentrations, Hounsfield units, gray scale values (GY)] and compared to corresponding unaffected reference tissue. Similar measures were obtained in DECT images of a peristalsis phantom. Wilcoxon signed-rank and paired t tests were used to compare results between different image reconstructions.Results: Peristalsis-related streak artifacts were found in 49 (49%) of the DECT examinations. Artifacts were significantly more severe in 70, 120, and water(-iodine) images than in iodine(-water) images (qualitative readout P < 0.001, each). Quantitative measurements were significantly different between the artifact and the reference tissue in 70, 120 keV, and water(-iodine) images (P < 0.001 for both HU and GY for each image reconstruction), but not significantly different in iodine(-water) images (iodine concentrations P = 0.088 and GY P = 0.111). Similar results were seen in the peristalsis DECT phantom study.Conclusions: Peristalsis-related streak artifacts seen in 70, 120 keV, and water(-iodine) images are substantially reduced in iodine(-water) images at rsDECT.