Monte Carlo evaluation of specific dose constants in water for 125I seeds.
Monte Carlo evaluation of specific dose constants in water for 125I seeds.
复制标题
蒙特卡罗评估水中 125I 种子的特定剂量常数。
DOI:
10.1118/1.596181
复制
发表时间:
1988
期刊:
影响因子:
3.8
通讯作者:
Williamson,JF
中科院分区:
文献类型:
--
作者:
Williamson,JF
To clinically utilize relative three‐dimensional dose distribution data for125I seeds in water, the specific dose constant must be known. This constant is the ratio of absolute dose rate in medium, 1 cm from the source on its transverse bisector, to source strength. We have used the Monte Carlo method to calculate specific dose constants in water for three types of125I seeds (models 6711, 6701, and 6702). Our photon transport code realistically models the complex internal structure of these interstitial sources as well as the exposure standardization experiments conducted at the National Bureau of Standards which form the basis of125I source strength specification. In addition, relative attenuation factors for the three seed types are presented. Our results indicate that published data overestimate the specific dose constant by 10% to 14%.