Evaluation of motion artifact metrics for coronary CT angiography.

Evaluation of motion artifact metrics for coronary CT angiography.
复制标题

DOI:
10.1002/mp.12720
复制
发表时间:
2018-03
期刊:
影响因子:
3.8
通讯作者:
Schmidt TG
Schmidt TG
中科院分区:
医学3区
文献类型:
--
作者:
Ma H;Gros E;Szabo A;Baginski SG;Laste ZR;Kulkarni NM;Okerlund D;Schmidt TG

文献摘要

参考文献

被引文献

相似文献

This study quantified the performance of coronary artery motion artifact metrics relative to human observer ratings. Motion artifact metrics have been used as part of motion correction and best-phase selection algorithms for Coronary Computed Tomography Angiography (CCTA). However, the lack of ground truth makes it difficult to validate how well the metrics quantify the level of motion artifact. This study investigated five motion artifact metrics, including two novel metrics, using a dynamic phantom, clinical CCTA images, and an observer study that provided ground truth motion artifact scores from a series of pairwise comparisons. Five motion artifact metrics were calculated for the coronary artery regions on both phantom and clinical CCTA images: positivity, entropy, normalized circularity, Fold Overlap Ratio (FOR), and Low Intensity Region Score (LIRS). CT images were acquired of a dynamic cardiac phantom that simulated cardiac motion and contained six iodine-filled vessels of varying diameter and with regions of soft plaque and calcifications. Scans were repeated with different gantry start angles. Images were reconstructed at five phases of the motion cycle. Clinical images were acquired from 14 CCTA exams with patient heart rates ranging from 52 to 82 bpm. The vessel and shading artifacts were manually segmented by three readers and combined to create ground-truth artifact regions. Motion artifact levels were also assessed by readers using a pairwise comparison method to establish a ground truth reader score. The Kendall’s Tau coefficients were calculated to evaluate the statistical agreement in ranking between the motion artifacts metrics and reader scores. Linear regression between the reader scores and the metrics was also performed. On phantom images, the Kendall’s Tau coefficients of the five motion artifact metrics were 0.50 (normalized circularity), 0.35 (entropy), 0.82 (positivity), 0.77 (FOR), 0.77(LIRS), where higher Kendall’s Tau signifies higher agreement. The FOR, LIRS and transformed positivity (the fourth root of the positivity) were further evaluated in the study of clinical images. The Kendall’s Tau coefficients of the selected metrics were 0.59 (FOR), 0.53 (LIRS) and 0.21 (Transformed positivity). In the study of clinical data, a Motion Artifact Score, defined as the product of FOR and LIRS metrics, further improved agreement with reader scores, with a Kendall’s Tau coefficient of 0.65. The metrics of FOR, LIRS and the product of the two metrics provided the highest agreement in motion artifact ranking when compared to the readers, and the highest linear correlation to the reader scores. The validated motion artifact metrics may be useful for developing and evaluating methods to reduce motion in Coronary Computed Tomography Angiography (CCTA) images.
DOI: 10.1109/tmi.2004.828354
发表时间: 2004-07-01
影响因子: 10.6
作者:
Warfield, SK;Zou, KH;Wells, WM
通讯作者: Wells, WM
DOI: 10.1214/aoms/1177704472
发表时间: 1962-01-01
影响因子: --
作者:
PARZEN, E
通讯作者: PARZEN, E
DOI: 10.2214/ajr.14.13022
发表时间: 2015-01-01
影响因子: 5
作者:
Phelps, Andrew S.;Naeger, David M.;MacKenzie, John D.
通讯作者: MacKenzie, John D.
DOI: 10.1118/1.4725754
发表时间: 2012-07-01
期刊: MEDICAL PHYSICS
影响因子: 3.8
作者:
Tang, Qiulin;Cammin, Jochen;Taguchi, Katsuyuki
通讯作者: Taguchi, Katsuyuki
DOI: 10.1136/openhrt-2014-000096
发表时间: 2014
期刊: Open heart
影响因子: 2.7
作者:
Plank F;Friedrich G;Dichtl W;Klauser A;Jaschke W;Franz WM;Feuchtner G
通讯作者: Feuchtner G