Multi-site, multi-platform comparison of MRI T1 measurement using the system phantom.

Multi-site, multi-platform comparison of MRI T1 measurement using the system phantom.
复制标题

DOI:
10.1371/journal.pone.0252966
复制
发表时间:
2021
期刊:
影响因子:
3.7
通讯作者:
Jackson EF
Jackson EF
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Keenan KE;Gimbutas Z;Dienstfrey A;Stupic KF;Boss MA;Russek SE;Chenevert TL;Prasad PV;Guo J;Reddick WE;Cecil KM;Shukla-Dave A;Aramburu Nunez D;Shridhar Konar A;Liu MZ;Jambawalikar SR;Schwartz LH;Zheng J;Hu P;Jackson EF

文献摘要

参考文献

被引文献

相似文献

Recent innovations in quantitative magnetic resonance imaging (MRI) measurement methods have led to improvements in accuracy, repeatability, and acquisition speed, and have prompted renewed interest to reevaluate the medical value of quantitative T1. The purpose of this study was to determine the bias and reproducibility of T1 measurements in a variety of MRI systems with an eye toward assessing the feasibility of applying diagnostic threshold T1 measurement across multiple clinical sites. We used the International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) system phantom to assess variations of T1 measurements, using a slow, reference standard inversion recovery sequence and a rapid, commonly-available variable flip angle sequence, across MRI systems at 1.5 tesla (T) (two vendors, with number of MRI systems n = 9) and 3 T (three vendors, n = 18). We compared the T1 measurements from inversion recovery and variable flip angle scans to ISMRM/NIST phantom reference values using Analysis of Variance (ANOVA) to test for statistical differences between T1 measurements grouped according to MRI scanner manufacturers and/or static field strengths. The inversion recovery method had minor over- and under-estimations compared to the NMR-measured T1 values at both 1.5 T and 3 T. Variable flip angle measurements had substantially greater deviations from the NMR-measured T1 values than the inversion recovery measurements. At 3 T, the measured variable flip angle T1 for one vendor is significantly different than the other two vendors for most of the samples throughout the clinically relevant range of T1. There was no consistent pattern of discrepancy between vendors. We suggest establishing rigorous quality control procedures for validating quantitative MRI methods to promote confidence and stability in associated measurement techniques and to enable translation of diagnostic threshold from the research center to the entire clinical community.
DOI: 10.1186/s12968-016-0280-z
发表时间: 2016-09-22
期刊: Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
影响因子: --
作者:
Captur G;Gatehouse P;Keenan KE;Heslinga FG;Bruehl R;Prothmann M;Graves MJ;Eames RJ;Torlasco C;Benedetti G;Donovan J;Ittermann B;Boubertakh R;Bathgate A;Royet C;Pang W;Nezafat R;Salerno M;Kellman P;Moon JC
通讯作者: Moon JC
DOI: 10.3389/fnins.2017.00106
发表时间: 2017
影响因子: 4.3
作者:
Lee Y;Callaghan MF;Nagy Z
通讯作者: Nagy Z
DOI: 10.2214/ajr.139.2.215
发表时间: 1982-01-01
影响因子: 5
作者:
BYDDER, GM;STEINER, RE;LEGG, NJ
通讯作者: LEGG, NJ
DOI: 10.1016/j.neuroimage.2019.116364
发表时间: 2020-02-15
期刊: NEUROIMAGE
影响因子: 5.7
作者:
Gracien, Rene-Maxime;Maiworm, Michelle;Deichmann, Ralf
通讯作者: Deichmann, Ralf
DOI: 10.1148/radiol.2018180273
发表时间: 2018-12-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
Partridge, Savannah C.;Zhang, Zheng;Hylton, Nola M.
通讯作者: Hylton, Nola M.