Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: Conventional ceramic etching vs etch & prime one-step primer.
Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: Conventional ceramic etching vs etch & prime one-step primer.
复制标题
胶结二硅酸锂玻璃陶瓷的疲劳破坏载荷:传统陶瓷蚀刻与蚀刻
DOI:
10.1016/j.dental.2018.04.012
复制
发表时间:
2018
期刊:
影响因子:
--
通讯作者:
L. Valandro
中科院分区:
文献类型:
--
作者:
M. Scherer;C. Prochnow;A. B. Venturini;G. Pereira;T. Burgo;M. Rippe;L. Valandro
ObjectivesTo evaluate the effect of different glass-ceramic surface treatments and aging on the fatigue failure load of a lithium disilicate glass-ceramic adhesively cemented to a dentin analogue material.MethodsOne hundred and twenty (120) disc-shaped lithium disilicate specimens (Ø = 10 mm, thickness = 1.5 mm) were produced and randomly allocated (n = 20) into 6 groups, considering 2 study factors: “surface treatment” in 3 levels (SIL—silane application only; HF5+SIL—5% hydrofluoric acid etching and silane application; ME&P—etching with an one-step ceramic primer), and “storage” in 2 levels (baseline—storage for 7 days; aging—storage for 90 days + 12,000 thermal cycles). Ceramic discs were adhesively cemented to discs of a dentin analogue material (Ø = 10 mm, thickness = 2.0 mm) following the manufacturers’ instructions. The fatigue failure load was determined by the staircase approach (250,000 cycles; 20 Hz; initial load = 1050 N [∼70% of mean load-to-failure]; step size = 52.5 N [5% of initial load]). Micro-morphologic, fractographic, and atomic force microscope analysis were also performed. Fatigue failure load data were evaluated by one-way ANOVA, Bonferroni and t-tests for independent samples.ResultsHF5+SIL presented higher fatigue failure load in both conditions (baseline and aging); ME&P presented intermediary mean values, while the SIL group presented the worst performance. All groups had a statistically significant decrease in the fatigue performance after aging.SignificanceHydrofluoric acid followed by silane application showed the best fatigue performance for an adhesively-cemented lithium disilicate ceramic. Aging negatively influenced the fatigue performance for all tested groups.
DOI:
10.1002/jbm.b.30852
发表时间:
2008-01-01
影响因子:
3.4
作者:
Huang, Min;Thompson, V. P.;Soboyejo, W. O.
通讯作者:
Soboyejo, W. O.
DOI:
10.1016/j.dental.2016.12.010
发表时间:
2017
期刊:
Dental materials : official publication of the Academy of Dental Materials
影响因子:
--
作者:
Villefort,ReginaFurbino;Amaral,Marina;Pereira,GabrielKalilRocha;Campos,TiagoMoreiraBastos;Zhang,Yu;Bottino,MarcoAntonio;Valandro,LuizFelipe;deMelo,RenataMarques
通讯作者:
deMelo,RenataMarques