Transmission of vancomycin-resistant Enterococcus in a neonatal intensive care unit
Transmission of vancomycin-resistant Enterococcus in a neonatal intensive care unit
复制标题
DOI:
10.1097/01.inf.0000164762.03930.0a
复制
发表时间:
2005-06-01
影响因子:
3.6
通讯作者:
Snydman, DR
中科院分区:
文献类型:
--
作者:
Golan, Y;Doron, S;Snydman, DR
An outbreak of vancomycin-resistant Enterococcus transmission in our neonatal intensive care unit persisted despite strict contact precautions and cohorting of colonized neonates and their caregivers. After terminal cleaning was performed, incubators were found to harbor the neonates' clone of vancomycin-resistant Enterococcus. Transmission ceased after cohorting of incubators, suggesting the effectiveness of infection control measures targeting environmental contamination.