Improved reflectometer electron density profile measurements on DIII-D
Improved reflectometer electron density profile measurements on DIII-D
复制标题
DOI:
10.1063/1.1527251
复制
发表时间:
2003-03
影响因子:
1.6
通讯作者:
Gang Wang;L. Zeng;E. Doyle;T. Rhodes;W. Peebles
中科院分区:
文献类型:
--
作者:
Gang Wang;L. Zeng;E. Doyle;T. Rhodes;W. Peebles
Details are presented of recent improvements to hardware and analysis code components of the DIII-D density profile reflectometer system. The improvements to the hardware increased the system signal-to-noise ratio and reduced spurious reflections. An improved automated method is developed to accurately determine the zero density plasma start position. With these improvements the uncertainty in the zero density plasma start position is reduced from ∼7 to ∼2 mm, the position uncertainty with a fixed mirror target is reduced from ∼4 to ∼2 mm, and the time resolution is improved to 10 μs (previously ∼100 μs).