Total AC loss of Ag-sheathed Bi2223 tapes with various filament arrangements carrying AC transport current in AC parallel transverse magnetic field
Total AC loss of Ag-sheathed Bi2223 tapes with various filament arrangements carrying AC transport current in AC parallel transverse magnetic field
复制标题
DOI:
10.1088/0953-2048/20/3/005
复制
发表时间:
2007-01
影响因子:
3.6
通讯作者:
R. Inada;Kazunori Tateyama;Yuichi Nakamura;A. Oota;Chengshan Li;Ping-xiang Zhang
中科院分区:
文献类型:
--
作者:
R. Inada;Kazunori Tateyama;Yuichi Nakamura;A. Oota;Chengshan Li;Ping-xiang Zhang
For the applications of Bi2223 tapes as the strands to power cables with multilayer structures, the tapes must carry the AC transport current in an AC parallel transverse field with various field amplitudes depending on the layer positions. In this study, we experimentally investigated the total AC loss characteristics under parallel transverse field for Bi2223 tapes with various filament arrangements in their cross sections. The tapes with different filament arrangements in the final tape sections were prepared by a conventional powder-in-tube (PIT) process with drawing using round dies and a rectangular deformation process using a two-axial rolling (TAR) technique. Total AC losses in the tapes carrying AC transport current in an AC parallel transverse field were measured by means of the electromagnetic method. The measured loss values in the tapes were compared with several analytical models. Based on the experimental results, the influence of filament arrangements on total AC loss behaviour is discussed, under the different operating conditions with various amplitudes of current and applied field.