Results of catheter ablation of typical atrial flutter
Results of catheter ablation of typical atrial flutter
复制标题
DOI:
10.1016/j.amjcard.2004.04.058
复制
发表时间:
2004-08-15
影响因子:
2.8
通讯作者:
Onufer, J
中科院分区:
文献类型:
--
作者:
Calkins, H;Canby, R;Onufer, J
The purpose of this study was to evaluate the safety and efficacy of radiofrequency (RF) ablation of typical atrial flutter by using an 8-mm electrode catheter and a 100-W RF power generator. A limitation of previous trials of catheter ablation of atrial flutter is that the data were not collected as part of a prospective multicenter clinical trial. The study results associated catheter ablation of typical atrial flutter in a cohort of 150 patients with an 88% acute efficacy rate. At 6-month follow-up, recurrent typical atrial flutter was observed in 13% of patients. Of the 12 patients with typical atrial flutter recurrence, 4 were symptomatic and 8 were asymptomatic. Procedure duration was a significant predictor of typical atrial flutter recurrence. The 12-month rate for development of atrial fibrillation was 30%. Catheter ablation of atrial flutter was associated with significant improvements in 5 of 8 domains of the Short Form 36 Survey (quality of life) and significant decreases in 13 of the 16 symptoms of the Symptom Checklist. The device- or procedure-related complication rate was 2.7%. Skin burns occurred at the dispersive pad site due to stronger RF power in 3 patients. Use of a dual dispersive pad system mitigated this problem. Thus, the results of this study associated catheter ablation of atrial flutter with high acute efficacy, a small risk of recurrent atrial flutter, and an important risk of atrial fibrillation during follow-up. (C) 2004 by Excerpta Medica, Inc.