High power tests of first input couplers for cornell erl injector cavities
High power tests of first input couplers for cornell erl injector cavities
复制标题
DOI:
10.1109/pac.2007.4441248
复制
发表时间:
2007-06
期刊:
影响因子:
--
通讯作者:
V. Veshcherevich;S. Belomestnykh;P. Quigley;J. Reilly;J. Sears;W. Moller
中科院分区:
文献类型:
--
作者:
V. Veshcherevich;S. Belomestnykh;P. Quigley;J. Reilly;J. Sears;W. Moller
The first two RF power couplers for the ERL injector, currently under construction at Cornell University, have been fabricated. The couplers were assembled in the liquid nitrogen cryostat, built for their tests. A 15 kW CW IOT transmitter was available for coupler tests. A resonant ring was used for an additional increase of power. The couplers were successfully tested up to the goal power level of 50 kW CW. However, the first pair of couplers showed an excessive temperature rise at some points. Therefore, minor changes in the design have been done to improve cooling.