Multiphoton endoscopy
Multiphoton endoscopy
复制标题
DOI:
10.1364/ol.28.000902
复制
发表时间:
2003-06-01
期刊:
影响因子:
3.6
通讯作者:
Schnitzer, MJ
中科院分区:
文献类型:
--
作者:
Jung, JC;Schnitzer, MJ
Despite widespread use of multiphoton fluorescence microscopy, development of endoscopes for nonlinear optical imaging has been stymied by the degradation of ultrashort excitation pulses that occurs within optical fiber as a result of the combined effects of group-velocity dispersion and self-phase modulation. We introduce microendoscopes (350-1000 mum in diameter) based on gradient-index microlenses that effectively eliminate self-phase modulation within the endoscope. Laser-scanning multiphoton fluorescence endoscopy exhibits micrometer-scale resolution. We used multiphoton endoscopes to image fluorescently labeled neurons and dendrites. (C) 2003 Optical Society of America.