F Fermi National Accelerator Laboratory FERMILAB-Pub-97 / 092 Evaluation of Candidate Photomultiplier Tubes for the Upgrade of the CDF End Plug Calorimeter
F Fermi National Accelerator Laboratory FERMILAB-Pub-97 / 092 Evaluation of Candidate Photomultiplier Tubes for the Upgrade of the CDF End Plug Calorimeter
复制标题
F 费米国家加速器实验室 FERMILAB-Pub-97 / 092 用于 CDF 端塞热量计升级的候选光电倍增管的评估
DOI:
--
复制
发表时间:
1997
期刊:
影响因子:
--
通讯作者:
A. Ronzhin
中科院分区:
文献类型:
--
作者:
W. Koska;S. Delchamps;W. Kinney;D. Lewis;P. Limon;A. Ronzhin
The Collider Detector at Fermilab is upgrading its end plug calorimeter from a gas detector system to one using scintillating tiles read out through wavelength shifting fibers. This upgrade is required to take advantage of the increase in luminosity which the Tevatron will provide in the future. The tile-fiber calorimeter, which is longitudinally segmented into electromagnetic and hadronic sections, will be read out through 1,824 photomultiplier tubes. The performance requirements of the calorimeter demand that the PMTs have good response to light in the 500 nm region, provide adequate amplification for signals from minimum ionizing particles, provide linear response for peak anode currents up to 25 mA at a gain of 5x104, and fit into the restricted space at the rear of the plugs. For convenience, we also desire a single PMT and base combination be used for the electromagnetic and hadron calorimeters even though the required gains in these sections differ by a factor of 10. This paper describes the evaluation process used to determine the adequacy of the commercially available PMTs which appeared to meet our performance requirements.