A two-directional approach for grating based differential phase contrast imaging using hard x-rays
A two-directional approach for grating based differential phase contrast imaging using hard x-rays
复制标题
DOI:
10.1364/oe.15.001175
复制
发表时间:
2007-02-05
期刊:
影响因子:
3.8
通讯作者:
Bunk, O.
中科院分区:
文献类型:
--
作者:
Kottler, C.;David, C.;Bunk, O.
We report on a two-directional approach for grating based x-ray differential phase contrast imaging. In order to retrieve good quality and artifact-free phase images for quantitative analysis and image processing, particular emphasis is put on the algorithm for proper phase retrieval. Examples of application are discussed that demonstrate the functionality of the method even in cases where the one-dimensional phase integration fails completely. (c) 2007 Optical Society of America.