Energy Losses in Cross Junctions
Energy Losses in Cross Junctions
复制标题
交叉路口的能量损失
DOI:
--
复制
发表时间:
2010
期刊:
影响因子:
--
通讯作者:
William J. Rahmeyer
中科院分区:
文献类型:
--
作者:
Zachary B. Sharp;Michael C. Johnson;S. Barfuss;William J. Rahmeyer
Energy losses occurring in pipe junctions have been studied for many years. Head loss coefficients (K) are commonly used to characterize losses across elbows, tees, crosses, valves, and other pipe fittings. When accurate values of K are used, the flow rate and corresponding total head at any location in a pipe network can be calculated. While K is well defined for most pipe junctions and fittings, the literature has limited documentations of K for crosses. This study was commissioned to determine K for a wide range of flow combinations in a pipe cross with equal diameter pipes and varied flow combinations. This study provides and innovatively presents over 1,000 experimental values of K for designing and analyzing equal diameter pipe crosses.