The role of diffusion-weighted imaging in the detection of hepatic metastases from colorectal cancer: A comparison with unenhanced and Gd-EOB-DTPA enhanced MRI

The role of diffusion-weighted imaging in the detection of hepatic metastases from colorectal cancer: A comparison with unenhanced and Gd-EOB-DTPA enhanced MRI
复制标题

DOI:
10.1016/j.ejrad.2016.02.011
复制
发表时间:
2016-05-01
影响因子:
3.3
通讯作者:
Filippone, Antonella
Filippone, Antonella
中科院分区:
医学3区
文献类型:
--
作者:
Colagrande, Stefano;Castellani, Alessandro;Filippone, Antonella

文献摘要

被引文献

相似文献

目的:比较DWI与钆塞酸二钠增强MRI在结直肠癌肝转移灶检测中的作用。方法:本回顾性研究包括54例患者,115例肝转移灶,经伦理委员会批准。所有患者在MRI后两周内接受术中超声和手术切除。将图像分为4组,由两名放射科医生在不同的时间段进行分析:平扫T1-T2 w(A组),A + DWI(B组),A+钆酸二钠(C组),A + DWI+钆酸二钠(D组)。对于每组,报告了转移瘤的存在/大小/部位。观察者间一致性和统计学显著性分别采用Cohen 'skappa和Mc-Nemar's检验。A/B/C/D组的平均灵敏度值分别为84.3/92.1/95.6/97.3%。平均特异性、阳性预测值、阴性预测值和准确度值在各组中也显著且逐渐增加:特异性从62.5%(A组)增加至85.0%,阳性预测值从92.8%增加至97.3%,阴性预测值从41.0%增加至85.1%,准确度从81.1%增加至95.5%。对于每个读者从A到D,假阴性的数量逐渐decreasing.Conclusions:对于两个读者,DWI改善了所有的统计参数在未增强的检查,为结节无论是小于或大于1厘米,而在EOB增强检查DWI precedented增加特异性/阴性预测值。(C)2016爱思唯尔爱尔兰有限公司版权所有。
Objectives: To compare the role of DWI vs. gadoxetic-acid-disodium enhanced MRI in the detection of colorectal hepatic metastases.Methods: Fifty-four patients with 115 hepatic metastases were included in this retrospective study, approved by the Ethical Board. All patients underwent intraoperative-ultrasound and surgical resection within two weeks after MRI. Images were grouped in 4 sets, which were analyzed by two radiologists in different sessions: unenhanced T1-T2w (set A), set A plus DWI (set B), set A plus gadoxetic-acid-disodium (set C), set A plus DWI plus gadoxetic-acid-disodium (set D). For each set, metastases presence/size/site was reported. Interobserver agreement and statistical significance were assessed by Cohen's kappa and Mc-Nemar's test, respectively.Results: Readers' agreement was always very good (k > 0.80). Mean sensitivity values were 84.3/92.1/95.6/97.3% for set A/B/C/D, respectively. Mean specificity, positive predicted, negative predicted, and accuracy values strongly and progressively increased in the various set too: from 62.5% (set A) to 85.0% as for specificity, from 92.8% to 97.3% as for positive predicted value, from 41.0% to 85.1% as for negative predicted value, and from 81.1% to 95.5% as for accuracy. For each reader from set A to D, the number of false negatives progressively decreases.Conclusions: For both readers, DWI improved all statistical parameters in the unenhanced examinations, as for nodules either smaller or greater than 1 cm, while in the EOB-enhanced examinations DWI prevalently increased specificity/negative predictive value. (C) 2016 Elsevier Ireland Ltd. All rights reserved.