USE OF FLUORESCENT DYES IN THE DETERMINATION OF ADHERENCE OF HUMAN-LEUKOCYTES TO ENDOTHELIAL-CELLS AND THE EFFECT OF FLUOROCHROMES ON CELLULAR FUNCTION

USE OF FLUORESCENT DYES IN THE DETERMINATION OF ADHERENCE OF HUMAN-LEUKOCYTES TO ENDOTHELIAL-CELLS AND THE EFFECT OF FLUOROCHROMES ON CELLULAR FUNCTION
复制标题

DOI:
10.1016/0022-1759(94)90384-0
复制
发表时间:
1994-06-03
影响因子:
2.2
通讯作者:
STEVENS, WJ
STEVENS, WJ
中科院分区:
医学4区
文献类型:
--
作者:
DECLERCK, LS;BRIDTS, CH;STEVENS, WJ

文献摘要

被引文献

相似文献

许多超活体荧光染料可用于体外和体内研究白细胞功能。最广泛使用的荧光素酯,荧光素二乙酸酯,具有快速细胞外排的缺点,而最近开发的荧光探针没有表现出这种不便的特性。然而,它们对细胞功能的影响尚未在人类中进行彻底研究。在这项研究中,我们描述了一种简单,快速的荧光法测量细胞粘附内皮细胞,比较5种不同的荧光染料。此外,我们评估了荧光染料标记(CFDA、CFSE、BCECF-AM、钙黄绿素-AM或DiI)对各种细胞功能的影响,除了粘附外,还包括淋巴细胞增殖、粒细胞趋化性和超氧化物生成。钙黄绿素-AM和DiI被证明是对细胞功能影响最小的荧光染料。BCECF-AM对淋巴细胞增殖无明显影响,但对粒细胞超氧阴离子产生和趋化性有一定影响。CFDA对淋巴细胞和粒细胞功能均显示出有害影响,而CFSE则显示出中等结果。在粘附试验中,钙黄绿素-AM、CFSE和DiI表现良好。由于C12-DiI标记是均匀的,因此该探针也适用于粘附测试,尽管存在较高的背景染色。我们的结论是,荧光染料是强大的工具时,分析人类白细胞粘附内皮细胞。然而,由于荧光染料标记可以干扰其他细胞功能,荧光探针必须根据待研究的细胞类型和功能仔细选择。
A number of supravital fluorochromes are available to study leucocyte functions in vitro and in vivo. The fluorescein ester most widely used, fluorescein diacetate, has the disadvantage of rapid cellular efflux, whereas more recently developed fluorescent probes do not exhibit this inconvenient trait. However, their effect on cellular functions has not been thoroughly investigated in humans. In this study, we describe a simple and rapid fluorometric method for measuring cell adhesion to endothelium, comparing 5 different fluorochromes. Furthermore, we evaluated the effect of fluorescent dye labelling (with CFDA, CFSE, BCECF-AM, calcein-AM or DiI), on various cell functions, including, apart from adhesion, lymphocyte proliferation, granulocyte chemotaxis and superoxide production. calcein-AM and DiI proved to be the fluorochromes with the least effect on cellular function. BCECF-AM did not interfere with lymphocyte proliferation, but exhibited some influence on superoxide production and chemotaxis of granulocytes. CFDA showed a detrimental effect on both lymphocyte and granulocyte functions whereas CFSE gave intermediate results. In the adhesion assay, calcein-AM, CFSE and DiI performed comparably well. Since labelling with C12-DiI was homogeneous, this probe was also appropriate for the adhesion test, although somewhat higher background staining was present. We conclude that the fluorochromes are powerful tools when analysing the adhesion of human leucocytes to endothelial cells. However, since fluorochrome labelling can interfere with other cellular functions, the fluorescent probe has to be carefully chosen with regard to the cell type and function to be studied.