Estimation of the infiltration rate of UK homes with the divide-by-20 rule and its comparison with site measurements

Estimation of the infiltration rate of UK homes with the divide-by-20 rule and its comparison with site measurements
复制标题

用除以 20 规则估算英国住宅的渗透率及其与现场测量的比较

DOI:
10.1016/j.buildenv.2020.107275
复制
发表时间:
2020
影响因子:
7.4
通讯作者:
Pasos A
Pasos A
中科院分区:
工程技术1区
文献类型:
--
作者:
Pasos A

文献摘要

参考文献

被引文献

相似文献

建筑物消耗的能源占全球能源消耗的 40%,其中渗透引起的热损失占 30%。空气渗透是空气通过泄漏路径的意外流动,从根本上由建筑物的气密性决定。在英国,建筑物的气密性通常通过鼓风机门测试来测量,并结合除以20规则来预测空气渗透,该规则是SAP(标准评估程序:英国政府推荐的测量住宅能源等级的方法系统)采用的经验法则,用于估计渗透引起的住宅热损失。本文通过在英国东米德兰地区的 21 栋住宅中进行鼓风机门和示踪气体测试,评估了这一经验法则的代表性。结果表明除以 37 的规则更具代表性。还发现,当添加修改因子时,SAP 高估了空气渗透率。在某些情况下,错误率高达 500%。受影响最严重的住宅是较紧凑的住宅。建议修订除以 20 规则和修改因子的使用。
Buildings are responsible for 40% of the global energy usage to which infiltration-caused heat losses are responsible for 30%. Air infiltration is the unintended flow of air through leakage paths and fundamentally determined by the airtightness of a building. In the United Kingdom, building airtightness is conventionally measured through a blower door test and used to predict air infiltration in conjunction with the divided-by-20 rule, which is a rule of thumb that has been adopted by SAP (Standard Assessment Procedure: a UK government's recommended method system for measuring the energy rating of residential dwellings) for the estimation of the infiltration-caused heat losses for dwellings. This paper assesses the representativeness of this rule of thumb by carrying out blower door and tracer gas tests in twenty one dwellings located in the East Midlands Region of the United Kingdom. Results showed that a divide-by-37 rule would be more representative. It was also seen that the air infiltration rate is overestimated by SAP when modifying factors are added. The errors are as high as 500% in some cases. The most affected dwellings were the tighter ones. A revision of the usage of the divide-by-20 rule and the modifying factors is advised.
Cooper、Edward 和 Cheng、Xiaofeng 和 Wood、Christopher 和 Gillott、Mark C. 和 Tetlow、David 和 Riffat、Saffa 和 Simon、Lia De (2016) 在一系列英国家庭中对新型气密性测试仪进行现场试验
DOI: --
发表时间: 2015
期刊:
影响因子: --
作者:
E. Cooper;Xiaofeng Zheng;C. Wood;M. Gillot;David;Tetlow;S. Riffat;L. Simon
通讯作者: L. Simon
DOI: --
发表时间: 1986
期刊:
影响因子: --
作者:
M. Sherman;M. Modera
通讯作者: M. Modera
使用鼓风机门和脉冲方法对庇护环境中房屋大小的房间进行气密性测量的实验见解
DOI: --
发表时间: 2019
影响因子: 7.4
作者:
Xiaofeng Zheng;E. Cooper;Joe Mazzon;I. Wallis;C. Wood
通讯作者: C. Wood
裂缝流方程和尺度效应
DOI: --
发表时间: 1977
期刊:
影响因子: --
作者:
D. Etheridge
通讯作者: D. Etheridge
DOI: --
发表时间: 2013
期刊:
影响因子: --
作者:
O. Hassan
通讯作者: O. Hassan