Calibration and characterization protocol for spectral-domain optical coherence tomography using fiber Bragg gratings.

Calibration and characterization protocol for spectral-domain optical coherence tomography using fiber Bragg gratings.
复制标题

使用光纤布拉格光栅的谱域光学相干断层扫描的校准和表征协议。

DOI:
10.1117/1.3552602
复制
发表时间:
2011
影响因子:
3.5
通讯作者:
Chen,Zhongping
Chen,Zhongping
中科院分区:
医学3区
文献类型:
--
作者:
Eom,TaeJoong;Ahn,Yeh-Chan;Kim,Chang-Seok;Chen,Zhongping

文献摘要

被引文献

相似文献

本文提出了一种用于光纤布拉格光栅光谱域光学相干层析成像(SD-OCT)的校准方案,以获得定制光谱仪的对准因子和测量CCD像素域与波长域之间的非线性拟合函数。我们使用了五个中心波长不同的光栅,覆盖了宽带源光谱范围。它们都具有狭窄的光谱带宽(0.05 nm)和相同的反射率(92%),用于校准和对准定制的光谱仪。按照该方案实现的SD-OCT系统的对准系数为入射角44.37°,衍射角53.11°,焦距70.0 mm。根据对准因子重新计算光谱分辨率为0.187 nm。
We present a calibration protocol to obtain the alignment factors of a custom-made spectrometer and the nonlinear fitting function between the measured CCD pixel domain and the wavelength domain to apply to the spectral-domain optical coherence tomography (SD-OCT) using fiber Bragg gratings. We have used five gratings with different center wavelengths covering the broadband source spectral range. All have a narrow spectral bandwidth (0.05 nm) and the same reflectivity (92%) to calibrate and align the custom-made spectrometer. The implemented SD-OCT system following the proposed protocol showed the alignment factors as 44.37 deg incident angle, 53.11 deg diffraction angle, and 70.0-mm focal length. The spectral resolution of 0.187 nm was recalculated from the alignment factors.