Correlation between microtensile bond strength data and clinical outcome of Class V restorations
Correlation between microtensile bond strength data and clinical outcome of Class V restorations
复制标题
DOI:
10.1016/j.dental.2010.09.005
复制
发表时间:
2011-02-01
期刊:
影响因子:
5
通讯作者:
Rousson, V.
中科院分区:
文献类型:
--
作者:
Heintze, Siegward D.;Thunpithayakul, Chaiyasri;Rousson, V.
Objective. To determine if the results of resin-dentin microtensile bond strength (mu TBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations.Methods. Resin-dentin mu TBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The mu TBS testing was performed 8h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the mu TBS values were calculated subsequently.Results. Thirty-six clinical studies with 15 adhesive/restorative systems for which mu TBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p < 0.05). There was a significant correlation between mu TBS values both after 8h and 6 months of storage and marginal discoloration (r = 0.54 and r = 0.67, respectively). However, the same correlation was not found between mu TBS values and the retention rate, clinical index or marginal integrity.Significance. As mu TBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.