Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system.
Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system.
复制标题
DOI:
10.1186/cc6933
复制
发表时间:
2008
期刊:
影响因子:
15.1
通讯作者:
Zollinger, Andreas
中科院分区:
文献类型:
--
作者:
Hofer, Christoph K.;Senn, Alban;Weibel, Luc;Zollinger, Andreas
Stroke volume variation (SVV) has repeatedly been shown to be a reliable predictor of fluid responsiveness. Various devices allow automated clinical assessment of SVV. The aim of the present study was to compare prediction of fluid responsiveness using SVV, as determined by the FloTrac™/Vigileo™ system and the PiCCOplus™ system. In patients who had undergone elective cardiac surgery, SVVFloTrac was determined via radial FloTrac sensor, and SVVPiCCO and pulse pressure variation were assessed via a femoral PiCCO catheter. Stroke volume was assessed by transpulmonary thermodilution. All variables were recorded before and after a volume shift induced by a change in body positioning (from 30° head-up position to 30° head-down position). Pearson correlation, t-test, and Bland-Altman analysis were performed. Area under the curve was determined by plotting receiver operating characteristic curves for changes in stroke volume in excess of 25%. P < 0.05 was considered statistically significant. Body positioning resulted in a significant increase in stroke volume; SVVFloTrac and SVVPiCCO decreased significantly. Correlations of SVVFloTrac and SVVPiCCO with change in stroke volume were similar. There was no significant difference between the areas under the curve for SVVFloTrac and SVVPiCCO; the optimal threshold values given by the receiver operating characteristic curves were 9.6% for SVVFloTrac (sensitivity 91% and specificity 83%) and 12.1% for SVVPiCCO (sensitivity 87% and specificity 76%). There was a clinically acceptable agreement and strong correlation between SVVFloTrac and SVVPiCCO. SVVs assessed using the FloTrac™/Vigileo™ and the PiCCOplus™ systems exhibited similar performances in terms of predicting fluid responsiveness. In comparison with SVVPiCCO, SVVFloTrac has a lower threshold value.
登录
查看更多内容
影响因子:
8.8
作者:
Kumar, A;Anel, R;Parrillo, JE
通讯作者:
Parrillo, JE
影响因子:
9.8
作者:
Reuter, DA;Goresch, T;Goetz, AE
通讯作者:
Goetz, AE
影响因子:
38.9
作者:
Monnet, Xavier;Teboul, Jean-Louis
通讯作者:
Teboul, Jean-Louis
影响因子:
9.8
作者:
Rex, S;Brose, S;Buhre, W
通讯作者:
Buhre, W
影响因子:
3.6
作者:
Wiesenack, C;Fiegl, C;Keyl, C
通讯作者:
Keyl, C