A case study on the fire damage of the underground box structures and its repair works
A case study on the fire damage of the underground box structures and its repair works
复制标题
DOI:
10.1016/j.tust.2005.12.042
复制
发表时间:
2006-05
影响因子:
6.9
通讯作者:
S. H. Park;H. Oh;Y. Shin;S. Oh
中科院分区:
文献类型:
--
作者:
S. H. Park;H. Oh;Y. Shin;S. Oh
This study was performed to find out the damage of the underground box structures in Daegu Municipal Subway, South Korea, damaged by the fire broken out in February 18, 2003 through site inspection, material experiment and thermal stress analysis. As regards site inspection, net shape cracks, the stripping of concrete surface, the spalling of concrete, reinforcement exposure, were inspected. Likewise as regards material experiments, core specimens were collected in case of the region damaged seriously in order to evaluate uniaxial compressive strength. Thermal stress analysis was conducted centering around the two regions damaged seriously on the basis of the results of the site inspection, on purpose to understand the variations in the stress of concrete slab according to the process of time. In addition, repair and reinforcement works were practiced to the region damaged, with intent to sustain long-term safety and such works were also dealt with.