General. Reactions were performed in oven-dried glassware under an argon atmosphere with Teflon coated stir bars and dry septa. Dioxane was freshly distilled from Na/benzophenone ketyl prior to use. DMF was freshly distilled from CaH prior to use. Ni/Cg was stored and weighed out as a black powder in a glove box. All commercially available reagents were distilled either from CaH2 or molecular sieves under an inert atmosphere before use. Ni (NO3) 2•. 6H2O and graphite powder (1-2 µm) were purchased from Aldrich. 3, 4-Dimethyoxy-6-methyl-2-tosyloxy-benzaldehyde was purchased from Sarchem Labs. 8-Hydroxyquinaldine, salicylanilide, L-tyrosine, L-alanine ethyl ester, 6-hydroxyflavone, methyl 4-hydroxybenzoate, 3’-hydroxyacetophenone, and p-toluenesulfonyl chloride were purchased from Acros. All tosylates were prepared from the commercially available phenols except for the dipeptide. All microwave experiments were performed using a Personal Chemistry (now Biotage) Emrys Optimizer and 2-5 mL Pyrex reaction vessels that were flame dried under an argon atmosphere equipped with a Teflon stir bar and Teflon coated reaction vessel cap. ICP-AES analyses was performed on a Thermo Jarrell Ash IRIS plasma spectrometer. GC analyses were performed using an HP-5-capillary column (0.25 µm x 30 m; cross-linked 5% PH ME siloxane) and a time program with 5 min at 50 C followed by 20 C/min ramp to 280 C, and 20 min holding at this temp. Column chromatography was performed using Davisil Grade 633 Type 60A silica gel. TLC analyses was performed on commercial Kieselgel 60 F254 silica gel plates. NMR spectra were obtained on Varian Inova systems using CDCl3 as the solvent with proton and carbon resonance at 400 MHz and 100 MHz, respectively. FTIR spectra were obtained on an ATI Mattson Infinity series spectrometer neat on NaCl plates, and are reported in cm-1. Mass spectral data were acquired on a VF Autospec or an analytical VG-70-250 HF instrument.Preparation of Ni (II)/Cg. Graphite powder (3.75 g, 1-2 µm) was added to a 100 mL round bottom flask containing a stir bar. A solution of 727 mg (Aldrich, 24,407-4, Ni content by ICP determination: 92%; 2.30 mmol) Ni (NO3) 2• 6H2O in 35 mL deionized H2O was added to the graphite, and 40 mL of deionized H2O were added to wash down the sides of the flask. The flask was purged under argon and stirred vigorously for 1 min. The flask was submerged in an ultrasonic bath under a positive argon flow for 60 min. The flask was then attached to an argon purged distillation setup and placed in a pre-heated 175-180 C sand bath over a stir plate. As the distillation ended, the flask temperature rises