300-nm Imperceptible, Ultraflexible, and Biocompatible e-Skin Fit with Tactile Sensors and Organic Transistors
300-nm Imperceptible, Ultraflexible, and Biocompatible e-Skin Fit with Tactile Sensors and Organic Transistors
复制标题
DOI:
10.1002/aelm.201500452
复制
发表时间:
2016-04-01
影响因子:
6.2
通讯作者:
Someya, Takao
中科院分区:
文献类型:
--
作者:
Nawrocki, Robert A.;Matsuhisa, Naoji;Someya, Takao
DOI: 10.1002/aelm. 201500452 between a human touch, a touch of a metallic object, and no touch, while being immune to noise. Finally, ultralight, at 0.7 gm− 2, it allows for a multitude of applications where the weight of the electronics is of uttermost importance. A fully functioning e-skin, laminated on human subject’s hands, is shown in Figure 1a, with the e-skin device layout depicted in Figure 1 b. It incorporates simple resistive tactile sensors and organic field effect transistors (OFET) used to actively control the sensor information. OFET devices were electrically characterized with recorded average mobility of 0.34 cm 2 Vs− 1, and the ON/OFF ratio of≈ 10 5. Also, the threshold voltage Vt, was measured to be approximately− 1.72 V. The yield, calculated on 44 devices, was recorded as≈ 98%, with only a single faulty device. Figure 1 c demonstrates a transconductance curve of a typical OFET, measured for Vds=− 5 V, with Vt marginally higher than negative one volt. Figure 1 d shows an example of an output characteristic curve for V G in the range of 0 to− 5 volts. Following the fabrication process on a rigid glass slide, the devices were manually delaminated and subjected to physical/mechanical flexibility tests. The H2o-delaminated film was deposited onto a 60% prestretched elastomer that was subsequently relaxed. This resulted in a highly irregular surface, with multiple wrinkles for the film to adhere to. The elastomer was subsequently stretched 100 times to demonstrate good adhesion and physical durability of the devices. The devices were electrically characterized following the physical flexibility test, with a typical pre-and post-stretched transconductance curves shown in Figure 2 a. It can be seen that the device ON current underwent a marginal increase, with the poststretched average mobility increasing to 0.39 cm 2 Vs− 1, while the OFF and leakage (Ig) currents, as well as the ON/OFF ratios, remained largely unchanged. The V T also experienced a shift to− 1.03 V. Figure 2 b depicts SEM image of an OFET film, placed directly atop of a relaxed elastomer, after the device was electrically characterized. Because the fragile nature of the film did not allow for a direct cross-sectional analysis, angled top view was analyzed instead. The shown image reveals extremely folded and compliant nature of the film. Detailed analysis of the inset reveals a folded edge of the film (top right corner), allowing for extrapolation of a bending radius to being less than 2 µm. This, we believe, is the primary reason why our film can undergo such extreme bending, folding and elastomer stretching, while preserving its good electrical performance. The CVD-deposited biocompatible Parylene serves as the top and bottom (substrate) encapsulation layers, making it an ideal candidate for external and internal medical applications.[27–30] For our initial investigations of the biocompatibility of our e-skin, we have chosen a relatively simple and safe test, namelyThe ability to accurately monitor 3D structures, for instance changes of temperature or shape of printed circuit boards, packaged food, or biological organs, without affecting the structure being monitored, presents a unique set of challenges and has been termed imperceptible electronics.[1–5] To achieve such a hefty goal will require developing electronics and materials that are conformal and flexible. Because the bending thickness, and subsequently the conformability as well as adhesiveness to soft tissues, of a thin film is proportional to its thickness cubed,[6] decreasing its thickness can significantly reduce the bending stiffness making the devices much more conformal and more adhesive. A number of examples using high …