Top hat wound configuration for penetrating keratoplasty using the femtosecond laser - A laboratory model

Top hat wound configuration for penetrating keratoplasty using the femtosecond laser - A laboratory model
复制标题

DOI:
10.1097/01.ico.0000179739.31196.e8
复制
发表时间:
2006-04-01
期刊:
影响因子:
2.8
通讯作者:
Sarayba, MA
Sarayba, MA
中科院分区:
医学3区
文献类型:
--
作者:
Ignacio, TS;Nguyen, TB;Sarayba, MA

文献摘要

被引文献

相似文献

目的:为了评估机械稳定性和诱导散光的修改后的多平面“礼帽”伤口配置的全层穿透性角膜移植术(PK)使用飞秒激光相比,PK在实验室model.Methods:8人角巩膜轮辋安装在人工前房。将4份样本分配至传统PK组。四个样本使用飞秒激光进行了全层角膜移植术:从前房到基质中进行9.0 mm的圆柱形切口,然后在角膜深度的三分之二处进行环形(外径9.0 mm,内径7.0 mm)水平板层切除术,并从板层到角膜表面进行7.0 mm的圆柱形切口。机械稳定性进行了评价后放置的基本缝线和运行suture.Results:在“礼帽”PK组,伤口渗漏发生在19 3.36毫米汞柱放置的基本缝线和86.25 +/- 9.74毫米汞柱放置的运行suture. Results后。在传统PK组中,放置主缝线和连续缝线后分别在0 0 mm Hg和76. 25 +/-20. 98 mm Hg下发生渗漏。两种技术均诱导术后角膜曲率变陡。改良伤口组的平均K值平均变化为3.43 +/- 3.62 D,而传统PK组的平均K值平均变化为3.21 +/- 6.67 D。结论:发现飞秒激光产生的PK“礼帽”伤口配置比传统方法产生的伤口配置更具机械稳定性。
Purpose: To evaluate the mechanical stability and induced astigmatism of a modified multiplanar "top hat" wound configuration for full-thickness penetrating keratoplasty (PK) using the femtosecond laser as compared with PK in a laboratory model.Methods: Eight human corneoscleral rims were mounted on an artificial anterior chamber. Four samples were assigned to the traditional PK group. Four samples underwent full-thickness keratoplasty with the femtosecond laser: a 9.0-mm cylindrical cut was made from the anterior chamber into the stroma, followed by a ring-shaped (outer diameter 9.0 mm, inner diameter 7.0 mm) horizontal lamellar resection at two-thirds corneal depth and a 7.0-mm cylindrical cut from the lamellae to the corneal surface. Mechanical stability was evaluated after placement of the cardinal sutures and the running sutures.Results: In the "top hat" PK group, wound leakage occurred at 19 3.36 mm Hg after placement of the cardinal sutures and at 86.25 +/- 9.74 mm Hg after placement of the running sutures. In the traditional PK group, leakage occurred at 0 0 mm Hg and 76.25 +/- 20.98 mm Hg after placement of the cardinal sutures and running sutures, respectively. Both techniques induced steepening of the corneal curvature postop. The modified wound group showed a mean change in average K of 3.43 +/- 3.62 D, whereas the traditional PK group showed a mean change in average K of 3.21 +/- 6.67 D.Conclusion: The femtosecond laser-produced "top hat" wound configuration for PK was found to be more mechanically stable than that produced by the traditional method.