Structural health–monitoring system for roof structure of the Dalian gymnasium
Structural health–monitoring system for roof structure of the Dalian gymnasium
复制标题
大连体育馆屋面结构健康监测系统
DOI:
10.1177/1369433218819572
复制
发表时间:
2018
影响因子:
2.6
通讯作者:
Tao Jiang
中科院分区:
文献类型:
--
作者:
Hongnan Li;Chaolin Yuan;L. Ren;Tao Jiang
The roof of Dalian gymnasium was designed in the form of suspen-dome structure. A structural health–monitoring system has been developed for the roof structure to guarantee the safety condition during construction process as well as in future service. In this article, a monitoring scheme was proposed in detail according to the mechanical characteristics of the roof structure. Fiber Bragg grating sensors, inclinometers, and accelerometers were applied to measure necessary structural information. In order to interrogate different types of sensors, a novel data acquisition device of the structural health–monitoring system was also introduced and has achieved multitudinous physical variable synchronization acquisition. By analyzing the data obtained during the construction and normal operation of the gymnasium, the structural health condition was evaluated and the structural damage could subsequently be located.