Plasma creatinine determination in mice and rats: An enzymatic method compares favorably with a high-performance liquid chromatography assay
Plasma creatinine determination in mice and rats: An enzymatic method compares favorably with a high-performance liquid chromatography assay
复制标题
DOI:
10.1038/sj.ki.5001988
复制
发表时间:
2007-01-01
影响因子:
19.6
通讯作者:
Pill, J.
中科院分区:
文献类型:
--
作者:
Keppler, A.;Gretz, N.;Pill, J.
The use of the colorimetric Jaffe method for the measurement of creatinine in mouse and rat plasma has been criticized as prior studies have shown a dramatic overestimation. We compared a colorimetric picric acid, an enzymatic, and a high-performance liquid chromatography (HPLC) method to assess their appropriateness for routine measurements of creatinine in plasma of healthy and diseased mice (n = 61) and rats (n = 56). For the colorimetric Jaffe method a pronounced overestimation is confirmed. Additionally the method showed interference with hemoglobin already in a very low, non-visible concentration range in rat plasma. The enzymatic measurement demonstrated a hemoglobin interference in mice, only when hemolysis was visible. The comparison between HPLC and the enzymatic measurement gave a good agreement between both methods in both species. Therefore the enzymatic method fulfills the requirements for a routine screening test for plasma creatinine in healthy as well as diseased mice and rats over a broad concentration range.