SENSORY TRANSMISSION THROUGH LEMNISCAL PATHWAY DURING VOLUNTARY MOVEMENT IN CAT
SENSORY TRANSMISSION THROUGH LEMNISCAL PATHWAY DURING VOLUNTARY MOVEMENT IN CAT
复制标题
DOI:
10.1152/jn.1974.37.5.831
复制
发表时间:
1974-01-01
影响因子:
2.5
通讯作者:
COULTER, JD
中科院分区:
文献类型:
--
作者:
COULTER, JD
METHODSThe experiments were performed on eight unrestrained, unanesthetized cats bearing chronically implanted electrodes for recording responses in the left media1 lemniscus to single-shock stimulation of tile con trala teraX superficial radial nerve. A bipolar electrode in the biceps bra&ii muscle was used to monitor electromyographic(EMG) activity during flexion movements of the right forelimb. The surgical procedure for implanting the electrodes was aseptic and carried out under