The measurement of exhaled carbon monoxide is influenced by airflow obstruction
The measurement of exhaled carbon monoxide is influenced by airflow obstruction
复制标题
DOI:
10.1183/09031936.00.15117700
复制
发表时间:
2000-01-01
影响因子:
24.3
通讯作者:
Agustí, AGN
中科院分区:
文献类型:
--
作者:
Togores, B;Bosch, M;Agustí, AGN
The concentration of carboxyhaemoglobin (COHb) is often estimated from measurements of carbon monoxide in the exhaled air (COexh). This study investigates whether the presence of airflow obstruction significantly alters the relationship between COexh and COHb.Eighty-one regular smokers were prospectively studied and divided in four groups according to the presence and severity of airflow obstruction (none, mild, moderate, severe). In each subject, the authors measured in this order: 1) arterial blood gases; 2) haemoglobin concentration and COHb (by co-oxymetry); 3) COexh; 4) lung volumes; and 5) forced spirometry. The size of the measurement error (Delta CO) was calculated from the difference between COHb and COexh.Neither the smoking history nor COexh were different in the four groups of subjects studied. In contrast, Delta CO increased in parallel to the degree of airflow obstruction. Delta CO was >2% (a threshold value normally used in the clinic to separate smokers from nonsmokers) only in patients with severe airflow obstruction. A stepwise multivariate analysis showed that both forced expiratory volume in one second (FEV1) (percentage reference) and COHb contributed significantly (p