Automated measurement of pediatric cranial bone thickness and density from clinical computed tomography.

Automated measurement of pediatric cranial bone thickness and density from clinical computed tomography.
复制标题

通过临床计算机断层扫描自动测量儿童颅骨厚度和密度。

DOI:
10.1109/embc.2012.6346957
复制
发表时间:
2012
期刊:
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
影响因子:
--
通讯作者:
Larson-Prior,LindaJ
Larson-Prior,LindaJ
中科院分区:
--
文献类型:
--
作者:
Smith,Kirk;Politte,David;Reiker,Gregory;Nolan,TracyS;Hildebolt,Charles;Mattson,Chelsea;Tucker,Don;Prior,Fred;Turovets,Sergei;Larson-Prior,LindaJ

文献摘要

相似文献

正常儿童颅骨的颅骨厚度和密度测量将为多个学科提供信息,包括神经外科、光学和磁电生理成像以及头部创伤的生物力学建模。我们报告了一种新的方法,用于自动提取在体颅骨厚度和密度测量的儿童颅骨的基础上,X射线计算机断层扫描(CT)。数据是从儿科人群的临床图像库中获取的,其中没有发现任何病理。颅骨厚度和密度的措施,系统地获得整个颅骨。我们发现了一组与生理年龄相关的措施,这些措施可能在多个学科中被证明是有用的。
Skull thickness and density measures of normal pediatric crania would inform multiple disciplines including neurosurgery, optical and magnetoelectrophysiological imaging, and biomechanical modeling of head trauma. We report on a new method for automated extraction of in vivo skull thickness and density measures of pediatric crania based on x-ray computed tomography scans (CT). Data were obtained from a clinical image repository for pediatric populations in whom no pathology was noted. Skull thickness and density measures were systematically obtained across the calvarium. We find a set of measures that correlated with physiological age that are likely to prove useful in multiple disciplines.