Wet microwave digestion of diet and fecal samples for inductively coupled plasma analysis.
Wet microwave digestion of diet and fecal samples for inductively coupled plasma analysis.
复制标题
对饮食和粪便样品进行湿式微波消解,用于电感耦合等离子体分析。
DOI:
10.1021/ac00170a015
复制
发表时间:
1988
影响因子:
7.4
通讯作者:
D. Milne
中科院分区:
文献类型:
--
作者:
G. M. Schelkoph;D. Milne
A method for the microwave digestion of diet and fecal sam-ples from metabolic balance studies Is described. Samples, enclosed In vessels (CEM Corp.) made of Teflon PFA brand fluorocarbon resin with a nitric-hydrochloric acid mixture, were digested In a microwave oven for a period of up to 30 min. Inductively coupled plasma emission spectroscopic (ICP-ES) analysisof the dlgestates for eight different mineral elements Indicated excellent agreement with certified values In several NBS StandardReference Materials. Recoveries of 92-104% and precision between 0.1 and 9.3% relative standard deviation Indicated that this procedure was well suited for providing digested samples for elemental determination by ICP-ES.It is necessary todestroy and remove the organic matrix of samples prior to trace element analysis by atomic absorption spectroscopy or by inductively coupled plasma emission spectroscopy (ICP-ES). Gorsuch (1) has discussed many of the problems related to different dry-ashing and wet-ashing