Methods for Measuring Bioactive Molecules in Blood by a Smartphone Using Bioluminescent Ratiometric Indicators
Methods for Measuring Bioactive Molecules in Blood by a Smartphone Using Bioluminescent Ratiometric Indicators
复制标题
使用生物发光比率指示器通过智能手机测量血液中生物活性分子的方法
DOI:
10.1007/978-1-0716-2473-9_16
复制
发表时间:
2022
影响因子:
--
通讯作者:
Nagai T
中科院分区:
文献类型:
--
作者:
Hattori M;Itoh Y;Nagai T
Bioluminescent indicators facilitate determination of bioactive molecules in blood samples with high sensitivity. Using a bright luciferase, its bioluminescence (BL) can be easily detected by conventional light sensing devices. In this chapter, we describe a protocol to measure bioactive molecules in blood by taking the BL images with a smartphone camera. We exemplify the measurement of unconjugated bilirubin (UCBR) concentration in the blood of mice using a ratiometric bioluminescent UCBR indicator, BABI (bilirubin assessment with a bioluminescent indicator), and a smartphone camera. We show the UCBR concentration is easily determined through measuring the variance in the BL color with a smartphone camera. This method provides a practical method to lead to future point-of-care diagnosis with quick and simple procedures.