Correction to "Low-Resource Nucleic Acid Extraction Method Enabled by High-Gradient Magnetic Separation".

Correction to "Low-Resource Nucleic Acid Extraction Method Enabled by High-Gradient Magnetic Separation".
复制标题

对“高梯度磁分离实现的低资源核酸提取方法”的更正。

DOI:
10.1021/acsami.3c18419
复制
发表时间:
2024
影响因子:
9.5
通讯作者:
Haselton,FrederickR
Haselton,FrederickR
中科院分区:
材料科学2区
文献类型:
--
作者:
Pearlman,StephanieI;Leelawong,Mindy;Richardson,KellyA;Adams,NicholasM;Russ,PatriciaK;Pask,MeganE;Wolfe,AnnaE;Wessely,Cassandra;Haselton,FrederickR

文献摘要

相似文献

在最初的文章中,在12459页,在2.2节中,在乱向洗涤缓冲液的EDTA组成中有一个关键的错字,导致萃取化学失败。共向洗涤缓冲液的组成应为[84%乙醇,640 mM胍硫氰酸酯,1.6 mM Tris HCl (pH 8), 160 μM EDTA (pH 8)]。由于实验中使用了正确的缓冲液,因此此更正不会改变本工作的主要结论。
In the original article, on page 12459, in section 2.2, there was a critical typo in the EDTA composition of the chaotropic wash buffer, which causes the extraction chemistry to fail. The composition of the chaotropic wash buffer should be [84% ethanol, 640 mM guanidine thiocyanate, 1.6 mM Tris HCl (pH 8), and 160 μM EDTA (pH 8)]. This correction does not alter the major conclusions of this work because the correct buffer was used in the experiments.