Novice-performed point-of-care ultrasound for home-based imaging.

Novice-performed point-of-care ultrasound for home-based imaging.
复制标题

DOI:
10.1038/s41598-022-24513-x
复制
发表时间:
2022-11-28
期刊:
影响因子:
4.6
通讯作者:
Goldsmith, Andrew J.
Goldsmith, Andrew J.
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Duggan, Nicole M.;Jowkar, Nick;Ma, Irene W. Y.;Schulwolf, Sara;Selame, Lauren A.;Fischetti, Chanel E.;Kapur, Tina;Goldsmith, Andrew J.

文献摘要

参考文献

被引文献

相似文献

绩效的超声波(POCUS)可能可用于基于家庭的医疗保健在他们自己的房屋中使用手持式的pocus设备的8区lus和pocus专家都在自己的家中进行了8层扫描。和平均体重指数招募了23.7(SD 3.1)。 0.42)。新型扫描的解释性与专家扫描没有差异(在8个区域中有7个,IQR 6-8,p = 0.42)。
Patient-performed point-of-care ultrasound (POCUS) may be feasible for use in home-based healthcare. We investigated whether novice users can obtain lung ultrasound (LUS) images via self-scanning with similar interpretability and quality as experts. Adult participants with no prior medical or POCUS training, who were capable of viewing PowerPoint slides in their home and who could hold a probe to their chest were recruited. After training, volunteers self-performed 8-zone LUS and saved images using a hand-held POCUS device in their own home. Each 8-zone LUS scan was repeated by POCUS experts. Clips were independently viewed and scored by POCUS experts blinded to performing sonographers. Quality and interpretability scores of novice- and expert-obtained LUS images were compared. Thirty volunteers with average age of 42.8 years (Standard Deviation (SD) 15.8), and average body mass index of 23.7 (SD 3.1) were recruited. Quality of novice and expert scans did not differ (median score 2.6, interquartile range (IQR) 2.3–2.9 vs. 2.8, IQR 2.3–3.0, respectively p = 0.09). Individual zone quality also did not differ (P > 0.05). Interpretability of LUS was similar between expert and novice scanners (median 7 zones interpretable, IQR 6–8, for both groups, p = 0.42). Interpretability of novice-obtained scans did not differ from expert scans (median 7 out of 8 zones, IQR 6–8, p = 0.42). Novice-users can self-obtain interpretable, expert-quality LUS clips with minimal training. Patient-performed LUS may be feasible for outpatient home monitoring.
DOI: 10.1002/jum.15571
发表时间: 2021-09
期刊: Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
影响因子: --
作者:
Ma IWY;Hussain A;Wagner M;Walker B;Chee A;Arishenkoff S;Buchanan B;Liu RB;Mints G;Wong T;Noble V;Tonelli AC;Dumoulin E;Miller DJ;Hergott CA;Liteplo AS
通讯作者: Liteplo AS
DOI: 10.1016/j.jchf.2021.05.008
发表时间: 2021-09
期刊: JACC. Heart failure
影响因子: --
作者:
Pang PS;Russell FM;Ehrman R;Ferre R;Gargani L;Levy PD;Noble V;Lane KA;Li X;Collins SP
通讯作者: Collins SP
DOI: 10.1378/chest.07-2800
发表时间: 2008-07-01
期刊: CHEST
影响因子: 9.6
作者:
Lichtenstein, Daniel A.;Meziere, Gilbert A.
通讯作者: Meziere, Gilbert A.
DOI: 10.1016/j.ajem.2020.05.079
发表时间: 2020-12-01
影响因子: 3.6
作者:
Shokoohi, Hamid;Duggan, Nicole M.;Tung-Chen, Yale
通讯作者: Tung-Chen, Yale
DOI: 10.1016/j.jchf.2019.07.008
发表时间: 2019-10
期刊: JACC. Heart failure
影响因子: --
作者:
Platz E;Campbell RT;Claggett B;Lewis EF;Groarke JD;Docherty KF;Lee MMY;Merz AA;Silverman M;Swamy V;Lindner M;Rivero J;Solomon SD;McMurray JJV
通讯作者: McMurray JJV