Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings.

Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings.
复制标题

不同 In-Ceram 氧化铝内冠边缘贴合度的显微 CT 评估。

DOI:
--
复制
发表时间:
2009
期刊:
European Journal of Esthetic Dentistry
影响因子:
--
通讯作者:
G. Eliades
G. Eliades
中科院分区:
--
文献类型:
--
作者:
Stavros Pelekanos;Maria Koumanou;S. Koutayas;S. Zinelis;G. Eliades

文献摘要

被引文献

相似文献

该研究的目的是评估通过四种不同技术制造的不同 In-Ceram 氧化铝陶瓷芯的边际配合度。四组四个 In-Ceram 氧化铝芯材样本 (Vita),每组厚度 0.6 mm,使用四种不同的技术从母模制造而成:SL 组,注浆成型技术(In-Ceram 系统); CL组,仿形铣削技术(Celay系统); CR 组是 CAD/CAM 系统(Cerec inLab 系统),WO 组是电沉积浸渍技术(Wol-Ceram)。将岩心样本安装到主模具上后,使用显微断层扫描设备(1072 micro-CT,Sky-Scan)对其进行扫描。数据集由软件(TView v1.1、SkyScan)处理,并生成每个岩心的 10 个垂直截面。在这些显微断层扫描横截面上,以微米尺度(微米)测量边缘间隙(MG)和绝对边缘差异(MD)。滑铸和电沉积浸渍技术分别呈现出 22 微米和 35 微米 MG 的最佳结果(α<5%)。 CAD/CAM 系统的 MG 为 55 微米。此外,注浆成型和电沉积浸渍技术分别在 50 微米和 60 微米的 MD 下呈现出最佳结果(α<5%)。滑铸技术和 Wol-Ceram 系统呈现出最佳的边缘拟合效果,其次是 Cerec inLab,它呈现出临床上可接受的结果。显微断层扫描分析似乎是评估牙齿修复体边缘配合的可靠方法。
The aim of the study was to evaluate the marginal fit of different In-Ceram alumina ceramic cores manufactured by four different techniques. Four groups of four In-Ceram alumina core specimens (Vita), each 0.6 mm in thickness, were fabricated from a master die using four different techniques: Group SL, the slip-cast technique (In-Ceram system); Group CL, the copy-milling technique (Celay system); Group CR, a CAD/CAM system (Cerec inLab system) and Group WO, the electro-deposition dipping technique (Wol-Ceram). After the core specimens were fitted on the master die, they were scanned with the use of a microtomography device (1072 micro-CT, Sky- Scan). Datasets were processed by software (TView v1.1, SkyScan) and 10 vertical sections from each core were generated. On these microtomographic cross-sections the marginal gap (MG) and the absolute marginal discrepancy (MD) were measured in microscale (microm). The slip-cast and the electro-deposition dipping techniques presented the best results of MG with 22 microm and 35 microm, respectively (alpha<5%). The CAD/CAM system presented an MG of 55 microm. In addition, the slip-cast and the electro-deposition dipping techniques presented the best results of MD with 50 microm and 60 microm, respectively (alpha<5%). The slip-cast technique and the Wol-Ceram system presented the best marginal fit, followed by Cerec inLab, which presented clinically acceptable results. Microtomography analysis seemed to be a reliable method of evaluating the marginal fit of dental restorations.