Validation of PROMIS Physical Function Instruments in Patients With an Orthopaedic Trauma to a Lower Extremity

Validation of PROMIS Physical Function Instruments in Patients With an Orthopaedic Trauma to a Lower Extremity
复制标题

DOI:
10.1097/bot.0000000000001493
复制
发表时间:
2019-08-01
影响因子:
2.3
通讯作者:
Gershon, Richard C.
Gershon, Richard C.
中科院分区:
医学3区
文献类型:
--
作者:
Rothrock, Nan E.;Kaat, Aaron J.;Gershon, Richard C.

文献摘要

被引文献

相似文献

目的:评估患者报告结果测量信息系统(PROMIS)移动计算机适应性测试(CAT)和PROMIS身体功能8a简表的可靠性、收敛效度、已知组效度和反应性。设计:前瞻性队列研究。设置:两个I级创伤中心。患者:连续接触接受治疗的孤立性下肢创伤损伤的合格成人(n = 402,在时间1时同意,中位数=治疗后80天)。6个月后,122(30.3%)完成了另一项评估。干预:对患者进行横断面和纵向监测。主要结果测量:地板和天花板效应,可靠性(边际信度和Cronbach’s alpha),收敛效度,已知组区分效度(负重状态和骨折严重程度)和反应性(Cohen's d效应量)进行PROMIS活动性CAT、PROMIS身体功能8a简表和其他5项身体功能指标的评估。PROMIS PFSF 8a和足踝能力测量日常生活活动指数具有天花板效应。两个PROMIS措施表现出良好的内部一致性可靠性(平均边际可靠性0.94和0.96;克朗巴赫的α = 0.96)。收敛有效性的支持与其他措施的身体功能(r = 0.70-0.87)的高相关性。已知组的有效性的负重状态和骨折的严重程度是支持的反应性(活动CAT效应大小= 0.81;身体功能简表8a = 0.88)。结论:PROMIS活动CAT和身体功能8a简表表现出可靠性,收敛和已知组的判别效度,并在一个样本的患者下肢骨科创伤损伤的反应。
Objectives: To evaluate the reliability, convergent validity, known-groups validity, and responsiveness of the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility Computer Adaptive Test (CAT) and PROMIS Physical Function 8a Short Form.Design: Prospective cohort study.Setting: Two Level-I trauma centers.Patients: Eligible adults with an isolated lower extremity trauma injury receiving treatment were approached consecutively (n = 402 consented at time 1, median = 80 days after treatment). After 6 months, 122 (30.3%) completed another assessment.Intervention: Cross-sectional and longitudinal monitoring of patients.Main Outcome Measurements: Floor and ceiling effects, reliability (marginal reliability and Cronbach's alpha), convergent validity, known-groups discriminant validity (weight-bearing status and fracture severity), and responsiveness (Cohen's d effect size) were evaluated for the PROMIS Mobility CAT, PROMIS Physical Function 8a Short Form, and 5 other measures of physical function.Results: PROMIS PFSF8a and Foot and Ankle Ability Measure Activities of Daily Living Index had ceiling effects. Both PROMIS measures demonstrated excellent internal consistency reliability (mean marginal reliability 0.94 and 0.96; Cronbach's alpha = 0.96). Convergent validity was supported by high correlations with other measures of physical function (r = 0.70-0.87). Known-groups validity by weight-bearing status and fracture severity was supported as was responsiveness (Mobility CAT effect size = 0.81; Physical Function Short Form 8a = 0.88).Conclusions: The PROMIS Mobility CAT and Physical Function 8a Short Form demonstrated reliability, convergent and known-groups discriminant validity, and responsiveness in a sample of patients with a lower extremity orthopaedic trauma injury.