A High Resolution BGO Calorimeter with Longitudinal Segmentation
A High Resolution BGO Calorimeter with Longitudinal Segmentation
复制标题
DOI:
10.1016/0168-9002(94)90611-4
复制
发表时间:
1994-09
影响因子:
1.4
通讯作者:
K. Kampert;E. Bohne;A. Claussen;F. Berger;D. Bock;R. Glasow;N. Heine;P. Mau;T. Peitzmann;M. Purschke;R. Santo;K. Steffens;D. Stüken;T. Awes;G. Young
中科院分区:
文献类型:
--
作者:
K. Kampert;E. Bohne;A. Claussen;F. Berger;D. Bock;R. Glasow;N. Heine;P. Mau;T. Peitzmann;M. Purschke;R. Santo;K. Steffens;D. Stüken;T. Awes;G. Young
We report on the construction and test results of a 8 × 8 module electromagnetic BGO calorimeter with both longitudinally non-segmented modules and modules with longitudinal segmentation for improved electron/hadron discrimination and two shower separation. The data have been taken mainly at the CERN PS accelerator at electron and pion momenta ranging from 0.5–6 GeV/c. The crystals are read out via large area silicon PIN photodiodes coupled to specially developed low-noise preamplifiers and pulse-processor modules with automatic gain range selection. We discuss the energy and position resolution as well as the performance for particle identification and two shower separation.