Detection of Inclusion in Molten Metal by Focused Ultrasonic Wave

Detection of Inclusion in Molten Metal by Focused Ultrasonic Wave
复制标题

聚焦超声波检测熔融金属中的夹杂物

DOI:
10.1143/jjap.39.3152
复制
发表时间:
2000
影响因子:
1.5
通讯作者:
D. R. França
D. R. França
中科院分区:
物理与天体物理4区
文献类型:
--
作者:
I. Ihara;C. Jen;D. R. França

文献摘要

被引文献

相似文献

本文尝试用包层金属缓冲棒聚焦超声脉冲回波技术探测650°C锌液中悬浮的杂质颗粒。聚焦的超声波由制作在缓冲杆端部的球形声透镜产生。在10 MHz下进行了实验。实验结果表明,利用所设计的聚焦缓冲棒,可以对锌液中的杂质颗粒进行检测。
An attempt for detecting impurity particles suspended in molten zinc at 650°C has been made using a focused ultrasonic pulse-echo technique with a clad metallic buffer rod. The focused ultrasonic waves are generated by a spherical acoustic lens which is fabricated at the end of the buffer rod. An experiment is carried out at 10 MHz. The result shows that impurity particles in molten zinc are detectable by using the presented focusing buffer rod.