Target volume shape variation during hypo-fractionated preoperative irradiation of rectal cancer patients
Target volume shape variation during hypo-fractionated preoperative irradiation of rectal cancer patients
复制标题
DOI:
10.1016/j.radonc.2009.04.022
复制
发表时间:
2009-08-01
影响因子:
5.7
通讯作者:
Marijnen, Corrie
中科院分区:
文献类型:
--
作者:
Nijkamp, Jasper;de Jong, Rianne;Marijnen, Corrie
Purpose: To quantify the day-to-day target volume shape variation in rectal-cancer patients treated with preoperative 5 x 5 Gy radiotherapy.Materials and methods: For 27 patients a prone position plan-CT (pCT) and five daily pre-treatment cone-beam-CT (CBCT) scans were acquired. A sub-region of the CTV (MesoRect, anus up to the cranial end of the mesorectal-fascia) was delineated on all scans. The MesoRect deformation was quantified by the distance between pCT- and CBCT-delineations and was stored in surface-maps. Finally, the influence of bladder and rectum filling on MesoRect deformation was evaluated. Data were analyzed for male and female patients separately.Results: A large range of systematic and random deformations, 1-7 mm (1SD), on different areas of the MesoRect were found. The maximum deformations were located at the upper-anterior-side of the MesoRect. For females the errors were up to 3 mm larger than for males. Small correlations, r(2)