Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
复制标题
DOI:
10.1056/nejmoa1907863
复制
发表时间:
2019-10-31
影响因子:
158.5
通讯作者:
Beck, R. W.
中科院分区:
文献类型:
--
作者:
Brown, S. A.;Kovatchev, B. P.;Beck, R. W.
BACKGROUNDClosed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes.METHODSIn this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring.RESULTSA total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (+/- SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61 +/- 17% at baseline to 71 +/- 12% during the 6 months and remained unchanged at 59 +/- 14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was